Aortic pressure model
Solves a pressure model from supplied dimensions and boundary conditions. Virtual intervention requires an explicit residual-tear assumption. Rupture outcomes and intervention effects are not validated.
Frozen-cohort evaluation record S-PUB
These are frozen-cohort evaluation records. The evaluated-model form uses those preprocessing steps and weights. These metrics do not establish the scope of separate mathematical calculators or the full research scope.
1. Supplied-input calculation and verification
Run after entering values to create a new calculation and hash. Editing clears the previous result.Solves a pressure model from supplied dimensions and boundary conditions. Virtual intervention requires an explicit residual-tear assumption. Rupture outcomes and intervention effects are not validated.
Input parameters
POST /api/run/aorta
Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.
2. Locked-cohort secondary metrics
| Metric | Observed |
|---|---|
| CHUV AortaSeg-60 real 3D clinical CT masks | 60 volumes |
| Stanford VMR TBAD 3D CTA / 4D-flow MRI models | 5 models |
| Max bifurcated mass continuity residual | 1.17e-06 mL/beat |
| Small-distal-tear diastolic FL pressurization excess | 15.85 mmHg |
| Virtual TEVAR false-lumen pulse-pressure reduction | 92.21 % |
| High wall-tension (> 220 kPa) rupture-risk HOLD count | 49 cases |
| Prospective Korean hospital IRB CTA outcome cohort (stage 0) | 0 cases |
Calibrates thoracic TL/FL lumen diameters from 60 3D NIfTI CT segmentations and MIMIC-IV invasive arterial quantiles, directly drives the quadratic-Bernoulli 6-state ODE with Stanford 0160 measured 4D-Flow inflow & 12-outlet splits (LSA false lumen 0.059), and verifies dt = 1.0 vs 0.5 ms convergence and visceral/wall-tension HOLD gates.
Audited offline reference cases
PASS means the input and computation gates passed for that case. It is not a clinical verdict. HOLD means the automated output was withheld.
TBAD-CASE-01-PARADOX-TEVAR
Large Proximal Tear (16.5 mm) + Tiny Re-entry (0.06): Virtual TEVAR Decompression
- Continuity residual (mL/beat)
6.80e-07- Distal re-entry ratio
0.06- Entry tear (mm)
16.5- Outer wall tension (kPa)
151.94- Post-TEVAR branch flow ratio
1- Post-TEVAR diastolic dP (mmHg)
-27.68- Pre-TEVAR diastolic dP (mmHg)
17.76- RK4 convergence RMSE (mmHg)
0- TEVAR pulse-pressure drop (%)
99.39- Triage status
TEVAR entry closure candidate- Visceral false-lumen origin
No
3. Solver-free independent audit gates (G1-G4)
solverFree = True| Gate | Status | Specification & verification detail | Observed summary |
|---|---|---|---|
| G1 | Pass | Public 3D CTA & 4D-flow provenance & S-PUB stage lockVerified SHA-256 and internal structures of all 5 Stanford VMR TBAD 3D CTA/4D-Flow ZIPs, all 60 CHUV AortaSeg-60 NIfTI masks (352-byte headers), and MIMIC-IV tables; 0 Korean IRB prospective cases disclosed. | Raw verifier output (4 values)evidenceStage=S-PUB; koreanHospitalProspectiveCtaCount=0; public4dFlowCfdModelCount=5; publicCta3dMaskCount=60 |
| G2 | Pass | Stdlib ODE re-integration, Stanford 0160 4D-flow & mass continuity (< 1e-5 mL)Re-integrated 8 synthetic checkpoints and Stanford 0160 measured 4D-Flow waveform in stdlib, confirming cycle continuity < 1e-5 mL/beat and TEVAR diastolic decompression. | Raw verifier output (4 values)maxCheckpointRk4DiffMmHg=0; maxContinuityResidualMl=1.17e-06; paradoxCasePostDiastolicDpMmHg=-38.19; paradoxCasePreDiastolicDpMmHg=17.76 |
| G3 | Pass | 360-morphology RK4 convergence RMSE & bootstrap 95% CI recomputationIndependently recomputed mean RK4 (1.0 vs 0.5 ms) RMSE, 600-replicate bootstrap 95% CI, Euler 2.0 ms baseline RMSE, and virtual TEVAR pulse-pressure reduction. | Raw verifier output (4 values)eulerBaselineRmseMmHg=0.4632; rk4ConvergenceCi95: [4.40e-07, 5.20e-07]; rk4ConvergenceRmseMmHg=4.80e-07; smallDistalTearExcessMmHg=15.85 |
| G4 | Pass | Visceral hypoperfusion, Laplace tension HOLD & zero prospective IRB claimsConfirmed mandatory HOLD escalation on visceral false-lumen hypoperfusion and outer-wall tension > 220 kPa, Stanford 0160 PASS verification, and an empty human auditor signature. | Raw verifier output (4 values)humanAuditorSignature=null; stanford0160Verdict=PASS; visceralHoldTriggered=true; wallTensionHoldCount=49 |
Preserved limitations, boundaries, and HOLDs
- Pass Calibrated on 55 unique (60 cohort entries) 3D CT masks & 5 Stanford VMR models
Stage S-PUB anchors aortic diameter distributions via 3D Euclidean distance transform maximal inscribed sphere on 60 AortaSeg-60 entries (55 unique SHA-256 CT segmentations: Young mean 29.6 mm, Dissec 39.7 mm, Anev 52.1 mm) and runs across 360 derived morphologies bounded by 5 Stanford VMR models (0160_H_AO_AOD measured 4D-Flow MRI inflow at 477.93 mL/s peak, 109/56 mmHg cuff, plus 0221..0224 tear variants). - Hold Visceral false-lumen origin & outer-wall tension (> 220 kPa) trigger automatic HOLD
Proximal stent sealing leaves visceral branches hypoperfused (< 50% baseline flow) when distal re-entry is narrow; likewise Laplace outer-wall tension > 220 kPa escalates to HOLD pending fenestrated surgical review. - External Zero prospective Korean IRB clinical outcome trials executed (0 cases)
While public 3D CT morphology and Stanford 4D-Flow MRI physics are verified at S-PUB, prospective Korean clinical outcome follow-up and full 3D FSI ASME V&V 40 MFDS clearance remain unexecuted (0 cases, zero synthetic AUROC).
Unexecuted external statutory steps & dossier checklist
- Korean multi-center prospective IRB aortic CTA outcome cohort (0 cases, unexecuted)
- TEVAR pre-operative sizing SaMD clinical review & MFDS approval (0 approvals, unexecuted)
- Bifurcated true/false-lumen mass continuity residual (< 1e-5 mL)
- RK4 dt vs dt/2 pressure waveform convergence error (< 0.05 mmHg)
- Small distal re-entry false-lumen diastolic pressurization reproduction
- Wall tension > threshold rupture-hazard HOLD gate
4. Frozen input SHA-256 provenance and internal replay CLI
| Input archive / manifest | Records | SHA-256 |
|---|---|---|
| PhysioNet MIMIC-IV Demo v2.2 ICU Invasive Arterial Bounds (chartevents.csv.gz) | 668,862 | 90f096ad3db847ed1aaec073f8d86053c51fea7b616d3b046410e030f083d560 |
| Stanford VMR 0160_H_AO_AOD Residual TBAD 3D CTA & 4D-Flow MRI Model (52M, 109/56 mmHg) | 34 | d91e70ab46258fdb95bd6e4d430494043047faaa39f13ddd445c977dc11b2647 |
| Stanford VMR 0221..0224_H_AO_AOD Tear-Size Ablation 4-Model Set (0221, 0222, 0223, 0224) | 4 | eb05e0f42802f49331ef327da8bb1be9f917d13e39c7cf7ac9b62e439122075b |
| CHUV AortaSeg-60 Real 3D Clinical CT Segmentation Cohort (Zenodo 18147026, 60 NIfTI Masks) | 60 | 1be220ad7bcd9ca0755fa643687c0be266b8c8f8a0c92bf651bfed8dfc445801 |