Explore the medical research group

6 sites · 85 research, tool & source destinations

GALENOSResearch computation & execution records

IATHEONCancer mechanisms & treatment hypotheses

NOEMATHEONMental health mechanisms, measures & recovery

HEBEAging, regeneration & functional recovery

APOSTOLUSResearch sources & implementation contracts

TESTIEDIntegrity evidence for medical-event records

Calculations & specialist research

GALENOSResearch computation & execution records

Calculations & checks

IATHEONCancer mechanisms & treatment hypotheses

NOEMATHEONMental health mechanisms, measures & recovery

HEBEAging, regeneration & functional recovery

APOSTOLUSResearch sources & implementation contracts

TESTIEDIntegrity evidence for medical-event records

Audit receipt

Supplied surgical-record consistency

Compares supplied patient IDs, site, declared signatures and selected lab values. Does not read DICOM files or Korean consent documents; a pass is not surgical clearance.

Choose another tool

Interactive Medical Visualizer

Open full Atlas DB & 3D Lab

VitalDB Propofol Ce-BIS & Hemorrhage Monitor

Simulate Propofol effect-site concentration (Ce) against the BIS 40-60 window and blood-loss shock index.

Frozen-cohort evaluation record S-PUB

These are frozen-cohort evaluation records. The evaluated-model form uses those preprocessing steps and weights. These metrics do not establish the scope of separate mathematical calculators or the full research scope.

Fault-injected safety mismatch interception accuracy 0.9783 Target: >= 0.95 internal pre-set target
95% CI & denominator [0.9717, 0.9834] n=2,400
Baseline comparison 0.5879 Surface String-Match & Unadjusted 24h Washout Baseline
External CRO & IRB status 0 / 0 CRO: 0, Clinical IRB: 0

1. Supplied-input calculation and verification

Run after entering values to create a new calculation and hash. Editing clears the previous result.

Compares supplied patient IDs, site, declared signatures and selected lab values. Does not read DICOM files or Korean consent documents; a pass is not surgical clearance.

Input parameters

POST /api/run/safety
Fill a calculation example

Direct input: missing measurements are not filled automatically.

Inspect request inputs
{}
Ready
POST /api/run/safety

Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.

input SHA-256: pending output SHA-256: pending humanAuditorSignature: null

2. Locked-cohort secondary metrics

Metric Observed
Clean-procedure autonomous clearance specificity0.9683
Laterality, mirror-flip & spinal-level (L4-L5 vs L5-S1) interception1
CKD-EPI 2021 eGFR-adjusted NOAC/Antiplatelet washout interception0.96
Missing-consent-signature bedside HOLD escalation rate1
SNUH VitalDB distinct surgical stays anchored (S-PUB)2400 stays
Prospective live OR EMR/PACS interlock trials executed (stage 0)0 trials

Parses HL7 FHIR R4 Patient, ServiceRequest, Serum Creatinine Observation (LOINC 2160-0), and MedicationStatement resources, computes race-free CKD-EPI 2021 eGFR for Dabigatran/Apixaban/Rivaroxaban/Clopidogrel washout checks, compares DICOM (0020,0060) and portable X-ray lead-marker orientation against Korean spinal-level synonyms ('제4-5요추' vs 'L5-S1'), routes unsigned consents to HOLD, and pairs 32 locked Cholec80 test video IDs with structured sponge-count fault records.

Audited offline reference cases

PASS means the input and computation gates passed for that case. It is not a clinical verdict.

Pass Compute gate only, not a clinical verdict SURG-CASE-01-CHOLEC80-PASS

Concordant Laparoscopic Cholecystectomy (SNUH VitalDB + Cholec80 video49)

CKD-EPI 2021 GFR
69.77
Evidence Stage
S-PUB (SNUH VitalDB)
SNUH Stay Hash
00b74e1960
Sponge Count Delta
0

3. Solver-free independent audit gates (G1-G4)

solverFree = True
Gate Status Specification & verification detail Observed summary
G1PassSNUH VitalDB 2,400-stay provenance, Cholec80 lock & zero raw identifier checkVerified S-PUB anchoring on 6388 SNUH VitalDB surgical stays (2,400 distinct pseudonymous caseHashes, 8 real pre-op acute creatinine surges, zero raw subject identifiers, zero prospective OR interlock trials) and the Cholec80 split manifest (40/8/32, 0 overlap).
Raw verifier output (6 values)evidenceStage=S-PUB; lockedTestVideosCovered=32; manifestSha256=5bcd91385542801389843f00124c1b862b886a1ac2c856cd256271b370fd0fc4; prospectiveLiveOrInterlockTrials=0; vitaldbDistinctStaysAnchored=2400; vitaldbLongitudinalAcuteCrVerified=8
G2PassHL7 FHIR R4, DICOM (0020,0060)/(0008,103E) & CKD-EPI 2021 eGFR rule verificationIndependently recomputed CKD-EPI 2021 race-free eGFR across all 2,400 scenarios and verified 0 silent passes across 800 wrong-site/wrong-patient/spinal-level faults and 32 Cholec80 test video IDs with structured sponge-count fault records.
Raw verifier output (4 values)ckdEpi2021Mismatches=0; renalWashoutSilentPasses=0; spongeCountSilentPasses=0; wrongSiteOrPatientSilentPasses=0
G3PassFault-injected safety mismatch interception accuracy & Wilson 95% CIRecomputed interception accuracy = 0.978333 (2348/2400, 95% Wilson CI [0.971699, 0.983439] >= 0.95 internal pre-set target) vs 0.587917 surface string-match baseline.
Raw verifier output (7 values)baselineAccuracy=0.5879; fn=14; fp=38; interceptionAccuracy=0.9783; tn=1162; tp=1186; wilson95: [0.9717, 0.9834]
G4PassMissing-consent-signature HOLD gate & stale-lab boundary disclosureVerified 90/90 (1.0) missing-signature consents routed to HOLD, 128 total bedside HOLDs, and 14 stale-creatinine / OR-clock-drift residual misses.
Raw verifier output (3 values)missingSignatureHoldRate=1; residualBoundaryFnCount=14; totalHoldCount=128

Preserved limitations, boundaries, and HOLDs

  • Boundary Stage S-PUB anchored on 2,400 distinct SNUH VitalDB surgical stays (0 prospective OR trials)
    Binds every pre-op safety scenario's age, sex, and serum creatinine (plus 8 real -30d to -48h vs -48h creatinine surges) to 2,400 unique SNUH VitalDB surgical stays without raw subject identifiers or synthetic AUROC claims; on-premise hospital EMR/PACS live OR interlock trials remain unexecuted (0 cases).
  • Hold Missing consent signatures & handwritten corrections trigger bedside HOLD
    All 90/90 missing surgeon/witness signature scenarios and smudged handwritten laterality amendments (128 total HOLDs) require verbal time-out verification before incision.
  • Negative Residual misses when pre-admission creatinine masks real SNUH acute eGFR dip or OR clock drifts
    14 non-laterality boundary scenarios passed pre-op rules when -30d..-48h baseline VitalDB creatinine masked a real acute inpatient creatinine rise below eGFR 30 mL/min or anesthesia timestamps drifted by 3 minutes.

Unexecuted external statutory steps & dossier checklist

  • Prospective operating room EMR / PACS / wristband barcode live interlock pilot (0 trials, unexecuted)
  • KOIHA surgical time-out & MFDS SaMD clinical clearance (0 approvals, unexecuted)
  • 2,400-case FHIR R4 + DICOM + Korean consent fault-matrix detection accuracy
  • CKD-EPI 2021 eGFR calculation & NOAC pre-op washout window check
  • DICOM Laterality (0020,0060) vs consent site & spinal-level interlock
  • Missing signature or unparsed consent field automatic HOLD gate

4. Frozen input SHA-256 provenance and internal replay CLI

Public provenance JSON
Input archive / manifestRecordsSHA-256
SNUH VitalDB Open Perioperative Cohort Clinical Table (vitaldb_cases.csv.gz)6,388fbb832e0f97b41199c3d89440c58d10179a1c69be31746aecd9a7a9b181668f4
SNUH VitalDB Longitudinal Perioperative Laboratory Table (vitaldb_labs.csv.gz)928,44846c85e5b5fc3fa524ea84314db7f177fac01ff0049c2078ee99cc3c71fcd6fff
Cholec80 Locked 80-Procedure Phase Split Manifest (40 train / 8 val / 32 test)805bcd91385542801389843f00124c1b862b886a1ac2c856cd256271b370fd0fc4
Internal maintainer CLI (local repo .venv only): ./scripts/check