Solves a compartment model using supplied elastance, resistance and volume. Drug effects are input assumptions; patient-specific treatment response is not predicted.
Adjust LV contractility (Ees) and afterload (Ea) on the PV-loop and invoke live causal EKF on AWS.
SYNTHETIC DEMO INPUTS: not measured patient vitals. Only the two MAP values are typed; the 2 h MAP is interpolated and PP, HR and SpO2 are fixed demo constants. The signed result carries the same flag.
Frozen-cohort evaluation record S-PUB
These are frozen-cohort evaluation records. The evaluated-model form uses those preprocessing steps and weights. These metrics do not establish the scope of separate mathematical calculators or the full research scope.
Held-out ICU hypotensive instability AUROC (MAP < 65 mmHg)0.7954 AUROCTarget: AUROC > shock-index baseline + 0.05 AND MAP MAE and RMSE below early-window persistence
95% CI & denominator[0.7104, 0.872]98 subjects / 134 stays
Baseline comparison0.6498 AUROCStatic Linear Shock-Index Baseline
Run after entering values to create a new calculation and hash. Editing clears the previous result.
Solves a compartment model using supplied elastance, resistance and volume. Drug effects are input assumptions; patient-specific treatment response is not predicted.
Input parameters
POST /api/run/hemodynamics
Ready
POST /api/run/hemodynamics
Enter values and run. Examples are labeled. A numerical PASS does not establish clinical validity or full capability.
Closed-loop blood volume conservation residual per beat
2.00e-12 mL/beat
RK4 step-halving convergence (dt=1.0 ms vs 0.5 ms)
0.0001 mmHg
Hypotensive instability probability Brier score
0.2308 Brier
Patient-specific left/right ventricular elastance, systemic arterial resistance/compliance, and unstressed venous volume (E_max_lv, R_sys, C_art, V_un) are identified on baseline brachial ICU vitals mapped to central aortic pressure via least-squares, then propagated through carotid-sinus baroreflex negative feedback and integrated forward with a 6-compartment closed-loop RK4 solver at dt=1.0 ms (verified against dt=0.5 ms in solver-free audit). Inputs are restricted to observations charted and stored by admission + 6 hours for the 6-24 hour target window. Missing CVP uses a disclosed weak 7.5 mmHg prior. Instability is a fixed heuristic score, not a trained clinical probability. The target is any MAP below 65 mmHg in that future window, including persistent hypotension present at baseline.
Audited offline reference cases
PASS means the input and computation gates passed for that case. It is not a clinical verdict. HOLD means the automated output was withheld.
PassCompute gate only, not a clinical verdictGLN-32-HFREF-VASODIL
MIMIC-IV SHA-256 provenance, temporal split & zero raw ID leakageVerified SHA-256 hashes of all 5 gzipped MIMIC-IV Demo tables, confirmed SpO2/CVP/ABP/HR extraction across strictly chronological early vs future windows, and scanned output JSON against all raw subject_id/stay_id/hadm_id values (0 leaks).
Raw verifier output (6 values)files=5/5, stays=134, subjects=98, spo2Stays=134, cvpStays=23, leakedIds=0
G2
Pass
LV/RV RK4 conservation (< 1e-6 mL/beat) & dt=1.0 ms vs 0.5 ms convergenceIndependently re-integrated the 6-compartment LV+RV elastance ODE in pure Python across 12 checkpoints at dt=1.0 ms and dt=0.5 ms, confirming < 1e-6 mL/beat volume conservation, step-halving stability, and physiological vasodilator/inotrope stroke volume response.
Raw verifier output (3 values)maxVolDriftBeat=2.10e-12 mL, dt1vs05Diff=0.0001 mmHg, reintErr1ms=2.00e-04 mmHg
G3
Pass
Held-out hemodynamic MAE/RMSE & instability AUROC replayIndependently recomputed baseline inverse-fit MAE, held-out MAP/PP MAE & RMSE, and Mann-Whitney AUROC with 2000 subject-cluster bootstrap draws against the early-window persistence baseline. All forecasts were independently replayed using inputs available by ICU admission + 6 hours.
Raw verifier output (3 values)metricIntegrityVerified=true; summary=AUROC=0.7954 vs 0.6498, MAP MAE=5.78 vs 6.76 mmHg, PP MAE=8.70 vs 8.06 mmHg; unmetPerformanceTargets: []
G4
Pass
ASME V&V 40 out-of-domain safety HOLD and empty human signatureVerified the physiological out-of-domain HOLD case, that each case records its metrics with the live input it was run on, and an empty human auditor signature.
Raw verifier output (4 values)solverFree=True, holdCase=True, hygieneIssues=0, humanSignature=None
Preserved limitations, boundaries, and HOLDs
BoundaryBaroreflex forecast beats MAP persistence, while pulse pressure reflects unmodeled cuff & therapy shifts Central-aortic pulse-amplification inverse fitting reduces early MAP MAE to 0.84 mmHg, and carotid baroreflex feedback lowers 6-24 h held-out MAP MAE to 5.78 mmHg (RMSE 7.68 mmHg vs persistence MAE 6.76 / RMSE 8.98 mmHg). Held-out brachial pulse pressure MAE remains 8.70 vs 8.06 mmHg because post-cutoff medication changes are not inputs.
HoldOut-of-domain tachyarrhythmia, severe hypoxemia & cardiogenic shock route to HOLD At HR > 155 bpm, E_max_lv < 0.50 mmHg/mL, SpO2 < 85%, or MAP < 42 mmHg, diastolic filling truncation and right-left ventricular interdependence require invasive Swan-Ganz or mechanical circulatory support evaluation; automated fluid titration is suspended via HOLD.
Negative0D lumped compartmental ODE cannot localize regional coronary stenosis or valve regurgitation jets While 6-compartment LV+RV RK4 integration preserves total blood volume to 2.10e-12 mL/beat (< 1e-6 mL/beat) and converges within 0.0001 mmHg between dt=1.0 ms and dt=0.5 ms, spatial transvalvular velocity jets and regional wall-motion defects require 3D echo/CFD.